On 00:05 by Unknown   No comments

Archive for category Bihl Wiedemann

BWU1567, BW1653, BWU1773,BWU1773, BWU1703, BWU1568, BW1654, BWU17

1 AS-i master
PROFIBUS slaveRecognition of duplicate AS-i addresses

AS-i Earth Fault Detector integrated

AS-i Noise Detector integrated
Art. no.BWU1567
Art. no.BW1653Class 1 Div. 2
(Group A, B, C & D, T-Code 4)
BWU1773BWU1703AS-i 3.0 from ID no. 12470, without RS232
diagnosis interface, without recognition of
duplicate AS-i addresses
Operating currentmaster power supply
approx. 200 mA out of AS-i circuit
Operating voltageAS-i voltage 30 V DC
PROFIBUS interfaceaccording to DIN 19 245 Part 3
Serial interfaceRS 232-
Baud rates9,6 KBaud up to 12000 KBaud, automatic recognition
DP functionsimaging of the AS-i slaves as I/O Data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
AS-i cycle time150 μs*(number of slaves + 2)
Displays
LCDdisplaying slave addresses and error messages
LED green (power)power on
LED green (PROFIBUS)PROFIBUS master recognized
LED red (config error)configuration error
LED green (U AS-i)AS-i voltage OK
LED green (AS-i active)AS-i normal operation active
LED green (prg enable)automatic address programming enabled
LED yellow (prj mode)master is in configuration mode
Buttons4
Voltage of insulation≥ 500 V
EMC directionsEN 61 000-6-2, EN 61 000-6-4
Operating temperature0°C … +55°C
Storage temperature-25°C … +85°C
HousingAS-i master housing in stainless steel
Dimensions (L, W, H in mm)120 / 75 / 83
Protection category (DIN 40 050)IP20
Tolerable loading reffering to impacts and vibrationsaccording to EN 61 131-2
Weight460 g

Accessories:
  • Software “AS-i Control Tools” with serial cable for AS-i master in stainlees steel (art. no. BW1602))
  • Serial PROFIBUS master (art. no. BW1258)
  • PROFIBUS DP master simulator (art. no. BW1257)

AS-i 3.0 from ID no. 12003 (see lateral Label)
2 AS-i masters

Recognition of duplicate AS-i addresses

AS-i Earth Fault Detector integrated

AS-i Noise Detector integrated

BWU1568: redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of power failure in one of the two AS-i networks

Art. no.BWU1568
Art. no.BW1654Class 1 Div. 2
(Group A, B, C & D,
T-Code 4)
BWU1774AS-i 3.0 from ID no. 12470,
without RS232 diagnosis
interface, without recognition
of duplicate AS-i addresses
Operating currentmaster power supply,
max. 200 mA out of AS-i circuit 1
(approx. 70 mA … 200 mA),
max. 200 mA out of AS-i circuit 2
(approx. 70 mA … 200 mA);
in sum max. 270 mA
approx. 200 mA out of AS-i circuit 1
approx. 70 mA out of AS-i circuit 2
PROFIBUS interfaceaccording to DIN 19 245 part 1-3
Serial interfaceRS 232-
Baud rates9,6 KBaud up to 12 000 KBaud, automatic recognition
DP functionsimaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
AS-i cycle time150 μs*(number of slaves + 2)
Displays
LCDdisplaying slave addresses and error messages
LED green (power)power on
LED green (PROFIBUS)PROFIBUS master recognized
LED red (config error)configuration error
LED green (U AS-i)AS-i voltage OK
LED green (AS-i active)AS-i normal operation active
LED green (prg enable)automatic address programming enabled
LED yellow (prj mode)master is in configuration mode
Buttons4
Voltage of insulation≥ 500 V
EMC directionsEN 61 000-6-2, EN 61 000-6-4
Operating temperature0°C … +55°C
Storage temperature-25°C … +85°C
HousingAS-i master housing in stainless steel
Dimensions (L, W, H in mm)120 / 75 / 83
Protection category
(DIN 40 050)
IP20
Weight460 g
Accessories:
  • Software “AS-i Control Tools” with serial cable for AS-i master in stainlees steel (art. no. BW1602)
  • Serial PROFIBUS master (art. no. BW1258)
  • PROFIBUS DP master simulator (art. no. BW1257)
  • Power supply 4A (art. no. BW1649)/8A (art. no. BW1593) for BW1569

AS-i 3.0 from ID no. 12003 (see lateral Label)
2 AS-i masters

Recognition of duplicate AS-i addresses

AS-i Earth Fault Detector integrated

AS-i Noise Detector integrated

BWU1569 and BW1655 in version
1 gateway, 1 power supply for 2 AS-i circuits:
Only 1 gateway + 1 AS-i power supply for 2 AS-i networks
Art. no.BWU1569
Art. no.BW1655
Class 1 Div. 2 (Group A, B, C & D, T-Code 4)
Operating currentversion “1 gateway, 1 power supply for 2
AS-i circuits”, approx. 250 mA
(PELV voltage)
PROFIBUS interfaceaccording to DIN 19 245 part 1-3
Serial interfaceRS 232
Baud rates9,6 KBaud up to 12000 KBaud, automatic recognition
DP functionsimaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
AS-i cycle time150 μs*(number of slaves+ 2)
Displays
LCDdisplaying slave addresses and error messages
LED green (power)power on
LED green (PROFIBUS)PROFIBUS master recognized
LED red (config error)configuration error
LED green (U AS-i)AS-i voltage OK
LED green (AS-i active)AS-i normal operation active
LED green (prg enable)automatic address programming enabled
LED yellow (prj mode)master is in configuration mode
Buttons4
Voltage of insulation≥ 500 V
EMC directionsEN 61 000-6-2, EN 61 000-6-4
Operating temperature0°C … +55°C
Storage temperature-25°C … +85°C
HousingAS-i master housing in stainless steel
Dimensions (L, W, H in mm)120 / 75 / 83
Protection category (DIN 40 050)IP20
Weight460 g

Accessories:
  • Software “AS-i Control Tools” with serial cable for AS-i master in stainlees steel (art. no. BW1602)
  • Serial PROFIBUS master (art. no. BW1258)
  • PROFIBUS DP master simulator (art. no. BW1257)
  • Power supply 4A (art. no. BW1649)/8A (art. no. BW1593) for BW1569

AS-i 3.0 PROFIBUS-DP-Gateway/Link in Stainless Steel
Basic Master
1 AS-i 3.0 Master
PROFIBUS slave
Art. no.BWU1746
Operating currentmaster power supply
approx. 200 mA out of AS-i circuit (max. 300 mA)
Operating voltageAS-i voltage 30 V DC
PROFIBUS interfaceaccording to DIN 19 245 part 3
Baud rates9,6 KBaud up to 12 000 KBaud, automatic recognition
DP functionsimaging of the AS-i slaves as I/O Data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
AS-i cycle time150 μs*(number of slaves + 2)
Displays
LEDdisplaying slave addresses and error messages
LED green (power)power on
LED green (PROFIBUS)PROFIBUS master recognized
LED red (config error)configuration error
LED green (U AS-i)AS-i voltage OK
LED green (AS-i active)AS-i normal operation active
LED green (prg enable)automatic address programming enabled
LED yellow (prj mode)master is in configuration mode
Buttons2
Voltage of insulation≥ 500 V
EMC directionsEN 61 000-6-2, EN 61 000-6-4
Operating temperature0°C … +55°C
Storage temperature-25°C … +85°C
HousingAS-i master housing in stainless steel
Dimensions (L, W, H in mm)120 / 45 / 40
Protection category (DIN 40 050)IP20
Tolerable loading reffering to impacts and vibrationsaccording to EN 61 131-2
Weight300 g

Accessories:
  • Software “AS-i Control Tools” (art. no. BW1203)
  • Serial PROFIBUS master (art. no. BW1258)
  • PROFIBUS DP master simulator (art. no. BW1257)
PROFIBUS DP Gateway/Link
with decoupling coils1 AS-i-Master
PROFIBUS-Slave

Duplicate address’ recognition
AS-i earth fault detector integrated

AS-i noise detector integrated

Graphical displayArt. no. BWU1891
Operating currentmaster power supply approx. 200 mA out of AS-i circuit
Operating voltageAS-i voltage 30 V DC
PROFIBUS interfaceaccording to DIN 19 245 Part 3
Serial interfaceRS 232
Baud rates9,6 KBaud up to 12000 KBaud, automatic recognition
DP functionsimaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
AS-i cycle time150 μs*(number of slaves + 2)
Displays
LCDdisplaying slave addresses and error messages
LED green (power)power on
LED green (PROFIBUS)PROFIBUS master recognized
LED red (config error)configuration error
LED green (U AS-i)AS-i voltage OK
LED green (AS-i active)AS-i normal operation active
LED green (prg enable)automatic address programming enabled
LED yellow (prj mode)master is in configuration mode
Buttons4
Voltage of insulation≥ 500 V
EMC directionsEN 50 295, EN 61 000-6-2, EN 61 000-6-4
Ambient operating temperature0°C … +55°C
Storage temperature-25°C … +85°C
HousingAS-i master housing in stainless steel
Dimensions (L, W, H)120 mm, 75 mm, 83 mm
Protection category (DIN 40 050)IP20
Tolerable loading reffering to impacts and vibrationsaccording to EN 61 131-2
Weight460 g

Accessories:
  • Software “AS-i Control Tools” with serial cable for AS-i master in stainless steel (art. no. BW1602)
  • Serial PROFIBUS master (art. no. BW1258)
  • PROFIBUS DP master simulator (art. no. BW1257)

0 nhận xét:

Đăng nhận xét